A biofeedback instrument that measures and displays muscle electrical activity in real-time for neuromuscular rehabilitation. Enables patients to develop awareness and control of muscle activation patterns during therapeutic exercises.
Manufactured by
China
DNO Medical, founded in 2006, specializes in wearable medical devices that are non-invasive, drug-free, and cost-effective. The company applies neuromodulation and EMG sensing technologies to develop mobile medical, diagnostic, and medical consumable products. DNO focuses on intelligent, data-driven solutions aimed at creating accessible "electronic drug" alternatives for patients worldwide.
✦ Product-Specific Coverage
Based on AI-matched alternatives related to this product across Suplivia's medical sourcing network.
Generated for this product
AI-matched supplier coverage based on related product alternatives.
zhongkeyidian(shenzhen)medical technology co.,ltd.
China · 2 relevant products
Shenzhen Konmed Technology co.,ltd
China · 10 relevant products
Sichuan Qianli-beoka Medical Technology Inc.
China · 1 relevant product
Mcube Technology Co., Ltd.
South Korea · 1 relevant product
NATECH SAS
France · 1 relevant product
BeiJing Remeda International Biology Technology Co,Ltd
China · 2 relevant products
Jiangsu Furui Technology Co., Ltd
China · 1 relevant product
lakhmedical
China · 1 relevant product
ION INTERNATIONAL Co., Ltd
South Korea · 1 relevant product
Hangzhou Zhengda Medical CO.,Ltd
China · 1 relevant product
9 more relevant manufacturers available
Get free access to all relevant manufacturers for this product.
See all manufacturers →See the full supplier coverage for this product
Get free access to all relevant manufacturers, sourcing countries, and product alternatives.
✓ Free for medical industry professionals.
from other manufacturers
from other manufacturers
12 of 32 closest product alternatives
zhongkeyidian(shenzhen)medical technology co.,ltd. · China
System that measures and displays muscle electrical activity to facilitate biofeedback training and neuromuscular rehabilitation. Used for motor control retraining and muscle function assessment.
Shenzhen Konmed Technology co.,ltd · China
Electromyography-based muscle therapy system providing real-time biofeedback for muscle rehabilitation. Used clinically for muscle strength recovery and neuromuscular re-education.
zhongkeyidian(shenzhen)medical technology co.,ltd. · China
A specialized biofeedback device for pelvic floor muscle assessment and rehabilitation using electromyographic signals. Enables real-time feedback for pelvic floor muscle training and therapy.
Sichuan Qianli-beoka Medical Technology Inc. · China
Biofeedback therapy system for neuromuscular re-education and functional recovery. Provides real-time feedback to patients during rehabilitation exercises.
Mcube Technology Co., Ltd. · South Korea
A biofeedback and electrical muscle stimulation system used for therapeutic applications in urological and pelvic floor rehabilitation. The device provides real-time feedback and therapeutic stimulation for patient treatment.
NATECH SAS · France
A rehabilitation equipment that provides real-time feedback on physiological parameters to help patients control bodily functions. Used in physical therapy and rehabilitation programs.
Shenzhen Konmed Technology co.,ltd · China
It is suitable for the treatment of cerebrovascular accidents, urinary incontinence caused by pelvic floor dysfunction, pain and muscular motor dysfunction, and postpartum rehabilitation. EMG Test Standard pelvic floor assessment and Quick body surface electromyography assessment. Detect the EMG value, compare the EMG value with the pre-specified range, and use it as a data reference. EMG Game When the device is working, it uses myoelectricity as physiological information, and feeds back to the trainees through interface graphic display, voice broadcast, game actions and other forms. ETS Detect the myoelectric value, compare the myoelectric value with the preset threshold, and there should be electrical stimulation output after reaching it. STIM Output electrical stimulation according to preset parameters and user-defined parameters. Record The historical data of patients can be viewed. System Setting Set the system status of the device. Patient Datas It is displayed on the lower left, and the patient files can be created, modified and deleted.
Shenzhen Konmed Technology co.,ltd · China
KM537 is a biofeedback and neuromuscular electrical stimulator. Four operation modules (EMG Test, EMG Game, ETS, and STIM) have been set up to assist patients in exercising. Independent dual-channel EMG signals acquisition. EMG data of multiple sites are obtained simultaneously to provide basis for treatment. Ergonomic design, effectively prevent the vaginal probe off and rotation, to ensure that treatment effect. The vaginal probe and electrode patches are tested and passed the bio-compatibility according to ISO 10993-1 requirements. To determine the activation timing of muscles. --Retaining of muscle activation. --Coordination of muscle activation. An indication of the force produced by muscle for control and maintenance of muscle contractions. --Relaxation muscle training. --Muscle re-education. --EMG Game for training muscle power, explosive power and speed. For EMG triggered STIM. --Stroke rehab by muscle re-education. --Relaxation of muscle spasms. --Prevention or retardation of disuse atrophy. --Increase local blood circulation. --Muscle re-education. --Maintaining or increasing range of motion. As nonimplanted electrical continence device. The device is a non-implanted muscle stimulator designed to provide electrical stimulation and neuromuscular re-education for the purpose of rehabilitation of weak muscles, pelvic floor muscles and restoration of neuromuscular control during the treatment of urinary continence.
Shenzhen Konmed Technology co.,ltd · China
KM536 is a biofeedback and neuromuscular electrical stimulator. Four operation modules (EMG Test, EMG Game, ETS, and STIM) have been set up to assist patients in exercising. Independent dual-channel EMG signals acquisition. EMG data of multiple sites are obtained simultaneously to provide basis for treatment. Ergonomic design, effectively prevent the vaginal probe off and rotation, to ensure that treatment effect. The vaginal probe and electrode patches are tested and passed the bio-compatibility according to ISO 10993-1 requirements. To determine the activation timing of muscles. --Retaining of muscle activation. --Coordination of muscle activation. An indication of the force produced by muscle for control and maintenance of muscle contractions. --Relaxation muscle training. --Muscle re-education. --EMG Game for training muscle power, explosive power and speed. For EMG triggered STIM --Stroke rehab by muscle re-education. --Relaxation of muscle spasms. --Prevention or retardation of disuse atrophy. --Increase local blood circulation. --Muscle re-education. --Maintaining or increasing range of motion. As nonimplanted electrical continence device. The device is a non-implanted muscle stimulator designed to provide electrical stimulation and neuromuscular re-education for the purpose of rehabilitation of weak muscles, pelvic floor muscles and restoration of neuromuscular control during the treatment of urinary continence.
Shenzhen Konmed Technology co.,ltd · China
Clinical biofeedback system providing real-time physiological monitoring and feedback during rehabilitation. Integrates with stimulation devices for enhanced muscle re-education and recovery.
Shenzhen Konmed Technology co.,ltd · China
KM530 is a biofeedback and neuromuscular electrical stimulator. Four operation modules (EMG Test, EMG Game, ETS, and STIM) have been set up to assist patients in exercising. Independent dual-channel EMG signals acquisition. EMG data of multiple sites are obtained simultaneously to provide basis for treatment. Ergonomic design, effectively prevent the vaginal probe off and rotation, to ensure that treatment effect. The vaginal probe and electrode patches are tested and passed the bio-compatibility according to ISO 10993-1 requirements. To determine the activation timing of muscles. --Retaining of muscle activation. --Coordination of muscle activation. An indication of the force produced by muscle for control and maintenance of muscle contractions. --Relaxation muscle training. --Muscle re-education. --EMG Game for training muscle power, explosive power and speed. For EMG triggered STIM --Stroke rehab by muscle re-education. --Relaxation of muscle spasms. --Prevention or retardation of disuse atrophy. --Increase local blood circulation. --Muscle re-education. --Maintaining or increasing range of motion. As nonimplanted electrical continence device. The device is a non-implanted muscle stimulator designed to provide electrical stimulation and neuromuscular re-education for the purpose of rehabilitation of weak muscles, pelvic floor muscles and restoration of neuromuscular control during the treatment of urinary continence.
Shenzhen Konmed Technology co.,ltd · China
The Konmed biofeedback neuromuscular stimulator KM580 uses the principles of neuromuscular electrical stimulation and biofeedback therapy, and has significant therapeutic effects on patients with sports dysfunction, swallowing, stroke, pelvic floor muscle dysfunction, and postpartum rehabilitation. Indications for Use For EMG --Retaining of muscle activation. --Coordination of muscle activation. An indication of the force produced by muscle for control and maintenance of muscle contractions. --Relaxation muscle training. --Muscle re-education. --EMG Game for training muscle power, explosive power and speed. For EMG triggered Stim and Mirror --Stroke rehab by muscle re-education. --Relaxation of muscle spasms. --Prevention or retardation of disuse atrophy. --Increase local blood circulation. --Muscle re-education. --Maintaining or increasing range of motion. As non-implanted electrical continence device The device is a non-implanted muscle stimulator designed to provide electrical stimulation and neuromuscular re-education for the purpose of rehabilitation of weak muscles, pelvic floor muscles and restoration of neuromuscular control during the treatment of urinary continence. Muscle re-education by application of external stimulation to the muscles necessary for pharyngeal contraction. Symptomatic relief and management of chronic (long-term), intractable pain. Adjunctive treatment in the management of post-surgical pain and post traumatic acute pain. Product function EMG 2 EMG Test Standard pelvic floor assessment and Quick body surface electromyography assessment. 1 EMG Work and Rest Training You can use Work and Rest for neuromuscular training. 5 Templates training (Biofeedback scenario) The Template training is designed for a wide range of neuromuscular disorders and is particularly useful for pelvic floor workout training. 6 EMG Games The EMG games are designed for biofeedback training. When the device is working, it uses myoelectricity as physiological information, and feeds back to the trainees through interface graphic display, voice broadcast, game actions and other forms. ETS Detect the myoelectric value, compare the myoelectric value with the preset threshold, and there should be electrical stimulation output after reaching it. ETS (EMG Triggered Stimulation) is primarily used for the training of weak skeletal muscles, but also found to be very effective in pelvic floor strengthening. Mirror Using mirror therapy (left/right discrimination exercises), the movement of the non-paralysed side of the limb is copied to the paralysed side. STIM Output electrical stimulation according to preset parameters and user-defined parameters. It is for Pelvic floor rehabilitation, Sports and muscular development, neuromuscular Rehabilitation, Swallow, TENS and Pain relief, NMES and FES. STIM programmes 19 Pre-set stim modes for Pelvic floor rehabilitation. 21 Pre-set stim modes for Sports and muscular development. 9 Pre-set stim modes for neuromuscular Rehabilitation. 10 Pre-set and Custom modes for Swallow. 10 Pre-set and Custom modes for TENS and Pain relief. 10 Custom modes for NMES and 10 Custom modes for FES. Simple single-phase or multiphase operation: multiphase allows EMG/ETS/STIM to be combined in one programme.
20 more product alternatives available
Create a free account to compare more product alternatives and supplier options.
© 2026 Suplivia · Home · Browse Products